Přeskočit navigaci (na obsah) / Skip navigation
Úvodní stránka Email Mapa stránek

DK power

 

Content:

DEFROST TWIN

Two-core heating circuits

Description:

DEFROST TWIN mass-produced two-wire heating system designed for applications melting ice and snow, such as yards, driveways, etc. These heating systems can be installed directly into the hot asphalt (160 ° C) or in concrete, sand, or under the stone pavement.

DEFROST TWIN heating circuits are supplied with cold outlets length 10m. Connection cold outlet is arranged so that does not exceed external dimensions of the heating cable.
This joint is integrated inside the casing of the heating cable marked with the symbol> SPLICE <, cold outlet then the symbols * * * * *.

Construction:

- Not stranded resistive wire
- XLPE working isolation
- Tinned ground / protective conductor
- Aluminum shielding reinforcement
- PVC outer sheath
- Outside diameter 7.5 mm
- Cold outlet 10 m
(2x1, 0 mm2)

Technical data:

- output of heating circuits from 640 to 3400 watts
- Linear heating power of 28 W / m
- Serial design with return wire does not require using external conductor
- Temperature resistance of outer jacket up to 65 ° C
- Minimum bending radius: 5 x outer cable diameter of (40 mm)
- Tolerance of resistance heating circuit -5 / +10%
- Construction voltage of 230 V
- Max. shielding conductor resistance: 18.5 Ω / km
- Max. hot asphalt temperature: 160 ° C

 
 