Přeskočit navigaci (na obsah) / Skip navigation
Úvodní stránka Email Mapa stránek

DK power

 

Content:

TXLP/1

Single core heating circuits

Description:

Heating circuits TXLP / 1 is ideal for underfloor heating of concrete structures. They can also be used for melting of ice and snow on outdoor surfaces, in gutter systems or for heating the soil.

Each heating circuit has a unique factory-made ​​connections cold ducts that its design does not exceed external dimensions of the heating cable. These connections are integrated inside the casing of the heating cable marked with the symbol> SPLICE <, then the symbols of the Cold outlets * * * * *.

Construction:

- Not stranded resistive wire
- XLPE isolation working
- Tinned ground / protective conductor
- Aluminum shielding
- PVC outer sheath
- Outside diameter 6.5 mm
- Cold pin length 2.25 m
(1x1, 0 mm2)

Technical data:

- Heating output circuits from 300 to 3150 watts
- Linear heating power 10 or 17 W / m
- Serial design
- Temperature resistance of the outer shell max. 65 ° C
- Minimum bending radius: 5 x outer cable diameter (35 mm)
- Tolerance of resistance heating circuit -5 / +10%
- The maximum working voltage of 300/500 V
- Design 230 V

 
 

data-sheet-txlp1-230v.pdf

Datasheet

66,05 kB

 
 
 

© 2008 DK power , Web Design and Web Development , CMS , eshop , CREATION.CZ,